The Phake-i is a patented surgical practice eye designed to improve surgical skills. Modeled after the human eye, the Phake-i is dimensionally correct and approximates the shape, size and feel of the human eye. The Phake-i can be easily paired with the Phake-i Face Form to create a realistic surgical environment. Made in the USA.
For Face Form see # 17105
DETAILS
- Central corneal thickness of 0.5mm
- Peripheral corneal thickness of 0.8mm
- Corneal diameter of 12mm
- Pupil: standard 4mm or dilated 8mm
- Lens: anterior capsular thickness of 0.0004"
- Lens material consists of central solid core and softer cortex, suitable for hydrodelineation, chopping, phaco-emulsification and irrigation/aspiration
- Realistic feel of an incision
- Suitable for stainless steel or diamond knives and other instruments
- Non-toxic, fully recyclable
PROCEDURES
The Phake-i is ideal for practicing key ophthalmic surgical procedures:
- Repair of corneal and scleral lacerations
- Corneal incisions and suturing
- Scleral flaps and scleral tunnels
- Intravitreal injections
- Capsulorrhexis
- Phaco-emulsification
- IOL (PC-AC) implants/explants
- Capsular Tension Rings
- Iris expanders/hooks
- Limbal Relaxing Incisions (LRI)
- Penetrating Keratoplasty
The Phake-i allows multiple different procedures to be performed on the same eye. However, a capsulotomy and phaco-emulsification can only be performed once.
SPECIFICATIONS
Each container includes four Phake-i Surgical Practice Eyes with 8mm pupils.